m302 p1. If you are using the web interface, go to the Gcode. m302 p1

 
 If you are using the web interface, go to the Gcodem302 p1  1 Reply Last reply Reply Quote 0 droftarts administrators @flyscha last edited by G10 P1 X0 Y0 Z0 ; Set tool 1 axis offsets G10 P1 R0 S0 ; Set initial tool 1 active and standby temperatures to 0C M302 S120 R110 ; Allow extrusion starting from 120°C and retractions already from 110°C Sending M302 P1 shows green as though it accepts the command, but the extrude & retract buttons are still grayed out

@agent0810 said in Homing advice: i was able to. e. 2"x12" backing boards 2"x4" studs 16. I thought I was having problems outputting STEP and DIR to the G320x, but actually it was a current issue in 3. if I'd have sent the extrude G code it probably would've extruded. Compared with the other two materials, this conformal metasurface has the best ability to bend. Once satisfied the extruder drive is working, re-enable cold extrusion prevention using the following command: M302 P0 Reset the Active temperature for Heater 1 back to 190C. 0C, min. If you are using the web interface, go to the Gcode. g. Business, Economics, and Finance. According to the docs, putting nothing or 0 means infinity. 1 Reply Last reply Reply Quote 0 M302 ; report current cold extrusion state M302 P0 ; enable cold extrusion checking M302 P1 ; disable cold extrusion checking M302 S0 ; always allow extrusion (disable checking) M302 S170 ; only allow extrusion above 170 M302 S170 P1 ; set min extrude temp to 170 but leave disabled I've processed a lot of the same flights in Terra, Pix4D, and Agisoft. I have some fillamentum wood filament, according to the website print temperature: 170 - 185 °C, however nothing prints within this range. 8 S1. Once installed, remove your existing tool defintion from config. -> no reaction at all - even after "M302 P1" What is working: Homing. M302 Allow Cold Extrudes [Pnn/Snn/Rmm] Allow cold extrude, set min extrude & retract temps M302 P1 ; Allow cold extrusion M552 Set IP, enable/disable network in[Pnn / Snn/ Rnn] P(IPV4 address) S(0|1 enable|disable, M552 S1 P192. Only users with topic management privileges can see it. G10 P1 X0 Y0 Z0 ; Set tool 1 axis offsets G10 P1 R0 S0 ; Set initial tool 1 active and standby temperatures to 0C M302 S120 R110 ; Allow extrusion starting from 120°C and retractions already from 110°C Failure to extrude in RepRapFirmware is usually caused by either cold extrusion prevention (but you have sent M302 P1 to disable that), or not having the tool selected. 0 S1 ; Enable network and acquire dynamic address via DHCP M586 P0 S1 ; Enable HTTPM302 P1;M563 P0 D3:4 ; Define tool 0 (no heaters assigned);M567 P0 E1:1;M584 E3:4;M302 P1 ;COLD EXTRUSION ON; Network M550 PXTP1 ; Set machine name M540 PBE:EF:DE:AD:FE:ED ; Set MAC address M552 P0. M302 P1 ; disable cold extrusion checking And yes each extruder is a tool T0 G1 E20 ; move current extruder 20mm T1 G1 E20 T2 G1 E20 Edited 2 time(s). 5 8" [422] 16Since the two ends of pole P1 bends and make a right angle at M, we have: ∠P1MN = 90° Also, the angle of elevation of the top of pole P1 from the point M is. 1 Reply Last reply Reply Quote 0. Suppose they are, in fact, 105mm apart. My pause button in webcontrol stopped working - it's ghosted with a stop-sign courser when I hover it. M302 P1 ; Allow Cold extrudes M98 Pmachine_maxtemp. @dc42 That doesn't seem to work. ) You can feed filament at 800mm/m (web interface max speed is 240mm/m), at 100mm at a time, until the filament is near the nozzle. I cannot get the extruder controls to show up in the web interface - it is greyed out. Command "M302 P1" works properly. This is the case even with M302 P1 at the bottom of the config. @jfavre said in Extruder motor not working. GCode and RepRapFirmware. 2 ; interpolate mbl probesG29 P3. So currently I've been slowly working my way throw learning Marlin and Visual studio as well as trying to build my 3d printer with the SKR2. Using Extruder-Motor by G-Code (after using M302 P1 to enable cold-extrusion) What catches my eyes is that the text "Heater1" etc. With the caveat that the extruder won't extrude when the hot end is cold, unless you override it with an M302 P1. 12/28/2022, 7:23:58 PM M302 Cold extrusion is forbidden (use M302 P1 to allow it), min. Then reduce the distance, and stop just before the filament disappears into the hot end. . Last edit at 01/11/2023 01:58AM by Dust. There is a web tool for this here which can make this easier for configuring another printer. 9. CryptoI did try a cold extrude M302 P1. So when i home it, x and y go to 225 and z goes to 0. retraction temperature 90. Life Sciences. 00 and cannot get the stepper motors of the extruders to work. Failure to extrude in RepRapFirmware is usually caused by either cold extrusion prevention (but you have sent M302 P1 to disable that), or not having the tool selected. Sending M302 P1 shows green as though it accepts the command, but the extrude & retract buttons are still grayed out. T0, you need to either heat up that tool, or enable cold extrusion by sending M302 P1. M569 P1. EDIT: OK, so you're using RRF 3. M302 P1 Now advance the filament using the jog buttons on the Manual Control tab, until it reaches the top of the heatsink. Technical Explanation 1. I copied the first 2 layer g-code here, and I would like to know if anyone have an idea to solve this issue. 4 S240 M307If calibrating cold, run M302 P1 (allows cold extrusion) If calibrating hot, heat your hotend to printing temp. 155 5. the X motor. I just wondered if there was a way of "embedding" it in the config files so that it runs by default. M98 Punload . If calibrating cold, run M302 P1 (allows cold extrusion) If calibrating hot, heat your hotend to printing temp. 16 and earlier, set the B parameter (beta value) to 4388. This topic has been deleted. From nozzles to swing pipes, Rain Bird offers a broad range of sprinkler parts and accessories to meet your irrigation needs. In the E0 port of the board, I didn't see the red led is on after I plug the motor. 5 (2022-11-30 19:41:16) running on Duet 3 Mini5plus WiFi (SBC mode)M302 P1 ; cold extrude: G92 × 0 Y0 Z0 ; set current position to {X = 0,Y = 0,Z = 0} G92 E0 ;zero the extruded length: G1 F200 E0. Ok if the motor is confirmed working, then at least cold extrusion should allow it to extruder as long as the tool is actually selected. M950 F1 C"fan1" Q500 ; create fan 1 on pin fan1 and set its frequency. M83 ; set extruder to relative mode echo "Start" G1 E60 F150 ; Extrude 60mm at 2. ; Tool definitions M563 P0 D0 H1 ; Define tool 0 M302 P1 ; Allow cold extrusion M140 H-1 ; Bed Off;Misc M83 ; Set extruder to relative mode M302 P1 ; Allow cold extrudes. @2:0 SENT: M302 RECEIVED: ok 0 RECEIVED: Cold extrusion allowed RECEIVED: wait Zum Test verwende ich immer Folgendes: G91 G1 E500 F3000 1-mal bearbeitet. oracledude 5 Dec 2021, 21:47. - Only upon M302 P1 to enable cold extrusion (if not heated) through pronterface, can I use the "Extrude" or "Reverse" button on the UI. M302 P1 ; disable cold extrusion checking And yes each extruder is a tool T0 G1 E20 ; move current extruder 20mm T1 G1 E20 T2 G1 E20 Edited 2 time(s). g. M302 P1 ; Allow cold extrusion Just enter the above code from your host software (pronterface or repitear) and you should be good to test the paste extruder. 3V pins on E1STOP then enter M557 E1 S0 (FW 2. short Signal and +3. 3 I have 2 toolheads When printing, changing to 2nd tool my print gets cancelled. What should I look for? F. Unmount the SD card and insert it into the Duet 2 Maestro board and power on. The macro folder can divided into sub directories to more easily organise your macros by type. 0C, min. To test for this, with the power off swap the E0 connector on the Duet with another one e. Sending T0 initiates the heater and then faults out. 2 E1. 1 OS hope it might work on it. After creating these and making all the connections we can move onto updating the firmware. I have almost everything working: Temp sensors All the axis drives including 4-Z steppers. Heater 1 fault: temperature rising too slowly: expected 2. extrusion temperature 160. 00" standard bore "competition" gasket for cast iron or aluminum cylinder heads on 302 and 351W production blocks. (You'll need to pull hard sometimes) Step 7 Printer: Anycubic Chiron, Firmware: Marlin 2. retraction temperature 90. 1 active and standby temperatures to 0C G10 P1 X0 Y0 Z0 ; Set tool 1 axis offsets G10 P1 R0 S0 ; Set initial tool 1 active and standby temperatures to 0C M302 S120 R110 ; Allow extrusion starting from 120°C and retractions already from 110°C G10 P1 X0 Y0 Z0 ; Set tool 1 axis offsets G10 P1 R0 S0 ; Set initial tool 1 active and standby temperatures to 0C M302 S120 R110 ; Allow extrusion starting from 120°C and retractions already from 110°C $\begingroup$ That fix, sending M302 P1 (the P1 is important) and then M500 can be done in any program that can communicate directly with the printer. org ] Reply Quote. These are commands that one may enter into the OctoPrint terminal tab. After replacing PCB managed to get everything up and running. g. With steps/mm so low you will get nothing like enough torque out of your motor to extrude anything, unless it is a really huge motor. Re: How can I move E steppers? January 11, 2023 02:36AMM302 P1 ; disable cold extrusion checking And yes each extruder is a tool T0 G1 E20 ; move current extruder 20mm T1 G1 E20 T2 G1 E20 Edited 2 time(s). com ], E3D tool changer, Robotdigg SCARA printer, Crane Quad and Ormerod. This will restore the last configured Revo insert on the next restart of the firmware. On Duet 3 if I send "M302P1" from the GCode console it returns "Error: Bad command". G10 P1 X0 Y0 Z0 ; Set tool 1 axis offsets G10 P1 R0 S0 ; Set initial tool 1 active and standby temperatures to 0C M302 S120 R110 ; Allow extrusion starting from 120°C and retractions already from 110°C Green - filament present. 0C. g underneath: M122 === Diagnostics === RepRapFirmware for Duet 3 Mini 5+ version 3. M302 P1; Axis Limits M208 X-50 Y0 Z0 U0 S1 ; set axis minima M208 X210 Y220 U260 Z200 S0 ; set axis maxima ; Endstops M574 X1 S1 P"io0" ; configure switch-type (e. My request is to add a connection to the Marlin firmware as it is done in program "LaserGRBL" Your GRBL_Plotter program is very good, adding this function would make it even. So no need to use M302. M117 Let's make some filament!;Turn on fan;M106. The Panasoic Felios F775 conformal metasurface is shown in Figure 9c. Extrusion Control in DWC unavailable, even after M302 P1. 00 and cannot get the stepper motors of the extruders to work. What is the trigger word to tell the firmware that we are starting a new layer? KulitorumHow bout if you heat up the hotend to 180?Hi *, I hope that somebody can help me here. 36°C/sec measured -0. +Z should move the bed down. I did hook it up to x axis physically and it worked. g. g at here G91 ; relative positioning G1 Z5 F6000 S2 <--(problem is here, remplace S2 by H2) ; lift Z relative to current position G90. . This command moves all axes t owards their end stops, un til they are reached,@jfavre Are you sure you have a tool selected (with T0, you will need that as well as the M302 P1)? What response did you get to M302 (before and after you set M302 P1)? What response did you get to M302 (before and after you set M302 P1)?@jfavre Are you sure you have a tool selected (with T0, you will need that as well as the M302 P1)? What response did you get to M302 (before and after you set M302 P1)? What response did you get to M302 (before and after you set M302 P1)?@Phaedrux said in Extruder motor not working. 2. In that case we must change the motor direction once again M569 P3 S1 ; physical drive 3 goes forwards Change S1 to S0@gixxerfast said in BL Touch not working: Which version of RRF are you using, ver 2? I can't see that you've mentioned it. How bout if you heat up the hotend to 180?How bout if you heat up the hotend to 180?How bout if you heat up the hotend to 180?M302 P1 ; Allow cold extrusion Just enter the above code from your host software (pronterface or repitear) and you should be good to test the paste extruder. gcode" and run that from an SD card. 0C, min. 4. Example output if disabled: echo:Cold extrudes are disabled (min temp 170C) Example output if enabled:M581 P1 T2 S0 R0 ;define trigger for filament auto load triggers trigger2. 0. Can not get E0 to extrude, M302 P1 = still grey buttonsI am using Cura to slice a simple cube. good evening . wordpress. M302 P1 ; Allow Cold extrudes; Thermistors M305 P0 T100000 B3950 R2200 H30 L0 M305 P1 T100000 B3950 R2200 H30 L0 M305 P2 T100000 B3950 R2200 H30 L0. Upon installation, you can see a new Revo directory in the Macros list which contains the following items:. 36°C/sec measured -0. CryptoBusiness, Economics, and Finance. Sending M302 P1 shows green as though it accepts the command, but the extrude & retract buttons are still grayed out. J'y connais pas grand chose dans les imprimantes 3D, moi jusque là, ça fonctionnais donc je ne m’intéressai pas trop au reste, mais là, je suis bien obligé, et donc je ne sais pas faire la commande G-code que tu m'indique, ou faire ça dans Repetier-Host ?We are using two different kinds of motors, but for the Z and E we are using we are using Nema 23 bipolar 2. Other possible causes are a bad stepper motor or cable. g . M302 P1;G92 E0. So please send T0 and M302 P1 and then see if you can send G1 E1 F100 to make. 2, Settings: FWRETRACT is not enabled, Slicer: Cura 4. Expected behavior: The Unload should ignore the temperature on the Hotend and do its. I updated webcontrol and firmware several times without error, but no change. 1. 22. La commande G-code M302 P1 permet l'extrusion a froid. 9 mm of feed stock: G92 E0 ;zero the extruded length again: G1 F900 ; set the feed-rate // Starting the print with Layer 0;Layer count: 1;LAYER:0: M107Preheat the hot end, if desired (or send M302 P1 if you intend to use the macro when the hot end is cold) Use M913 Ennn to reduce the motor current, if necessary (see #1 above) Use M83 to select relative extruder motion, in case the macro is. 23". 3 E40 ; set drive mapping. This value gives better accuracy at typical printing temperatures in the range 190 to 250C than the B value of 4267 quoted in the datasheet. extrusion temperature 160. M302 P1 ; allow cold extrusion. 00°C/sec. zip. Failure to extrude in RepRapFirmware is usually caused by either cold extrusion prevention (but you have sent M302 P1 to disable that), or not having the tool selected. 3 Then I think you should config the BLTouch differently: Have you read this bit, "Software setup (. droftarts administrators @flyscha last edited by . A typical piece of GCode sent to a machine running RepRapFirmware might look like this (The meaning of these codes (and more) is. To test for this, with the power off swap the E0 connector on the Duet with another one e. G28: home all axes. You could also put those commands in a normal text file with the file ending ". 00 B0 M665 H100 TO. 9mm of feed stock. Duet Web Control makes it easy to upload, edit and create new macros. M569 P0 S1 ; Reverse the X motor M563 P0 D0 H1 ; Define tool 1 G10 P0 S0 R0 ; Set tool 1 operating and standby temperatures M563 P1 D1 H2 ; Define tool 2 (un-comment this for dual nozzle machines) G10 P1 X19 S0 R0 ; Set tool 2 operating and standby temperatures (un-comment this for dual nozzle machines) M92 E447:447 ; Set. Failure to extrude in RepRapFirmware is usually caused by either cold extrusion prevention (but you have sent M302 P1 to disable that), or not having the tool selected. Only users with topic management privileges can see it. but if i want -z to go down shouldnt 0 be at the bottom? how would i swap that around, change the motor direction like you suggested in your last post?So when i home it, x and y go to 225 and z goes to 0. Reply Quote. M302 ; report current cold extrusion state M302 P0 ; enable cold extrusion checking M302 P1 ; disable cold extrusion checking M302 S0 ; always allow extrusion (disable checking) M302 S170 ; only allow extrusion above 170 M302 S170 P1. gpIn[0]. Heating Bed manually by G-Code. 2. CryptoM302 P1 ; enable cold extrusion G4 S1 ; wait for one second G1 E15 F500 ; load filament inside the gears. Still no luck with Extrusion Control jogging buttons. retraction temperature 90. M302 P1 (This will revert the next time you reset or power off the Duet, or you can send ‘M302 P0’. : Just need to find settings for Slice Engineering 300c thermistor, According to this document, you need to use the following in your M308 T100000 B4680 C6. 0. Example output if disabled: echo:Cold extrudes are disabled (min temp 170C) Example output if enabled:Hey all, my melzi finally died. Last edit at 01/11/2023 01:58AM by Dust. 2 the M302 P1 command doesn't help to allow the cold extrusion anymore. GameStop Moderna Pfizer Johnson & Johnson AstraZeneca Walgreens Best Buy Novavax SpaceX Tesla. g. 1 Reply Last reply Reply Quote 0. Failure to extrude in RepRapFirmware is usually caused by either cold extrusion prevention (but you have sent M302 P1 to disable that), or not having the tool selected. 2. M569 P0 S1 ; Reverse the X motor M563 P0 D0 H1 ; Define tool 1 G10 P0 S0 R0 ; Set tool 1 operating and standby temperatures M563 P1 D1 H2 ; Define tool 2 (un-comment this for dual nozzle machines) G10 P1 X19 S0 R0 ; Set tool 2 operating and standby temperatures (un-comment this for dual nozzle machines) M92 E447:447 ; Set. is not colored in WebControl as in the example screenshots i saw. In order to move the extruder, do I need set the temperature control input for the extruder heater? I have setup multiple tools that share a heater and have dedicated extruder drives. However, Slic3r inserts this code after the first Z-lift which is befo. TfreeN. To print at this lower temperature, g-code command M302 P1 was used to disable the printer’s cold extrusion checking. e. Serial No. M302 P1 ; Allow Cold extrudes M98 Pmachine_maxtemp. Macros also allow for naming gcodes with easier to remember names. M569 P0 S1 ; Reverse the X motor M563 P0 D0 H1 ; Define tool 1 G10 P0 S0 R0 ; Set tool 1 operating and standby temperatures M563 P1 D1 H2 ; Define tool 2 (un-comment this for dual nozzle machines) G10 P1 X19 S0 R0 ; Set tool 2 operating and standby temperatures (un-comment this for dual nozzle machines) M92 E447:447 ; Set. Looking for a way that is super native, standalone and low end way to get it to do that without using high level programming architecture, such as not using software that is running on python or what not. M83 ; set extruder to relative mode echo "Start" G1 E60 F150 ; Extrude 60mm at 2. To test for this, with the power off swap the E0 connector on the Duet with another one e. To test for this, with the power off swap the E0 connector on the Duet with another one e. Then select the plugin ZIP file and confirm the following steps. M109 S235 T0 ; set hotend temperature and wait. Send T0 before you try to extrude. Last edit at 01/11/2023 01:58AM by Dust. 7mm, the output contact is engaged @ about 0. wordpress. Don't disable the thermal runaway protection. Don't forget to send M302 P0 later to restore normal safety. Life Technologies was acquired by Thermo Fisher Scientific in January, 2014. The home position is detected by the punch slide HP sensor (PS302). Macros also allow for naming gcodes with easier to remember names. ) You can feed filament at 800mm/m (web interface max speed is 240mm/m),. Just need to find settings for Slice Engineering 300c thermistor, the temp reading slightly higher than actual measured with an TC thermometer. plan view. Heating Bed manually by G-Code. the X motor. G11: Unretract Used while Firmware retraction is configured in your slicer, along G10@gloomyandy are these values incorrect?; Tools M563 P0 S"volcano" D0 H1 F0 ; define tool 0 G10 P0 X0 Y0 Z0 ; set tool 0 axis offsets G10 P0 R0 S0 ; set initial tool 0 active and standby temperatures to 0CDoes the interface not respect M302? Hi! Can't figure out how to turn the e axis using the lcd knob while the extruder is cold. To test for this, with the power off swap the E0 connector on the Duet with another one e. 8. Still no luck with Extrusion Control jogging buttons. When setting my Anet A8 printer at that temp, the extruder motor doesn't turn by…Beat me to it! If the current tool doesn't have any heaters assigned to it, extrusion is allowed always. Check if extruder motor making any noise. M302 P1 (This will revert the next time you reset or power off the Duet, or you can send ‘M302 P0’. M302. 8 amps (JK57HS56-2804) with gear boxes for extra power. I would be very gratefull for any help. This topic has been deleted. Extruding some filament with M302 P1 enabled (cold extrusion) with bowden out of hotend Extruding some filament with hotend at required temperature Printing a test print. Home page Shop all products. However, a steps/mm value of 5. To test for this, with the power off swap the E0 connector on the Duet with another one e. g ; set bed and extruder max temperatures; --- SECTION: FANS ( ) ---M106 P0 S0 I0 F4 H-1 L0. I reduced. . . There is no minimum steps/mm set in the firmware. @patel said in how to change homing sequence: M3D promega There's a full guide to this on M3D's Promega support pages. microswitch) endstop. M302 works fine in a starting script or sent via console. This topic has been deleted. G10 P1 X0 Y0 Z0 ; Set tool 1 axis offsets G10 P1 R0 S0 ; Set initial tool 1 active and standby temperatures to 0C M302 S120 R110 ; Allow extrusion starting from 120°C and retractions already from 110°C G10 P1 X0 Y0 Z0 ; Set tool 1 axis offsets G10 P1 R0 S0 ; Set initial tool 1 active and standby temperatures to 0C M302 S120 R110 ; Allow extrusion starting from 120°C and retractions already from 110°C Sending M302 P1 shows green as though it accepts the command, but the extrude & retract buttons are still grayed out. . I have been clicking the 'retract' and 'extrude' button multiple times to push the plunger down to the correct position and to retract the plunger from the bottom of the cylinder after the print. droftarts administrators @flyscha last edited by . Failure to extrude in RepRapFirmware is usually caused by either cold extrusion prevention (but you have sent M302 P1 to disable that), or not having the tool selected. 00°C/sec. x) or M557 P1 S0 (FW >3. Sending M302 P1 shows green as though it accepts the command, but the extrude & retract buttons are still grayed out. +Z should move the bed down. M302 P1 (This will revert the next time you reset or power off the Duet, or you can send ‘M302 P0’. Heater 1 fault: temperature rising too slowly: expected 2. 3 ; Filter. . yello3d. . @dc42 That doesn't seem to work. 9 Windows 10 I am using a macro in reprapFirmware to pause the print for a certain length of time after evey layer. When tpostN is called, it is loaded into the y-splitter and hotend. 1 Z0. P1 S1 S1 S1 Lc 4 DTR COM1 5 Signal Ground 6 DSR. 7 Move a motor on delta printer On delta printers, the X,Y and Z movements does not correspond to a motor movement, while for commissioning, you may want to operate each motor. Other possible causes are a bad stepper motor or cable. If you are using the web interface, go to the Gcode. Zuletzt am 03. : till no luck with Extrusion Control jogging buttons. Only users with topic management privileges can see it. GameStop Moderna Pfizer Johnson & Johnson AstraZeneca Walgreens Best Buy Novavax SpaceX Tesla. M302 P1 ; disable cold extrusion checking And yes each extruder is a tool T0 G1 E20 ; move current extruder 20mm T1 G1 E20 T2 G1 E20 Edited 2 time(s). ; pre 3. I used M302 P1 and it worked fine when I was testing my new extruder stepper motor. 1 Reply Last reply Reply Quote 0. Connector for the extruder is plugged into second connection (i. 16 07:24. Direct drive: Remove your nozzle, hotend, or extruder. May 04, 2017 11:25PM. 3 (3. but if i want -z to go down shouldnt 0 be at the bottom? how would i swap that around, change the motor direction like you suggested in your last post?I did try a cold extrude M302 P1. M302 S160 ; lower cold extrusion limit to 160C {if filament_type[initial_tool]=="FLEX"}G1 E-4 F2400 ; retraction{else}G1 E-2 F2400 ; retraction{endif}. T0, you need to either heat up that tool, or enable cold extrusion by sending M302 P1. The problem is that the G1 code runs only once, no matter what I put after the L. Large delta printer [ miscsolutions. dmould. the X motor connector. @dsela. For example you can create a Macro. one immediately before X). 12/28/2022, 7:23:58 PM M302 Cold extrusion is forbidden (use M302 P1 to allow it), min. M98 Ppurge_bucket . The code sends commands to an Octoprint instance. Good morning. Ok I will try the. As well as selecting the tool with e. M302 P1 ; enable cold extrusion M201 E1000 ; reduce extruder acceleration M915 P3 S10 F0 R0 ; set stall detection threshold M913 E100 ; set extruder motor to reduced % current M83 ; relative extrusion G1 S1 E800 F3600 ; move fast 500mm of filament M913 E100 ; set extruder motor to full current M302 P0 ; disable cold extrusion G1 E50 F300. 9Hz when using S4 or P4 Q50 resp. For coding you should add M302 P0 to your ending gcode to re-enable the safety at the end of the file. G1 F200 E0. 1 Reply Last reply Reply Quote 0. What could be the causeMarlin defaults to "no cold extrusion". To test for this, with the power off swap the E0 connector on the Duet with another one e. and Terra makes the best looking meshes by far. But when i try to run it from DWC, I get the error: G10 P1 X0 Y0 Z0 ; Set tool 1 axis offsets G10 P1 R0 S0 ; Set initial tool 1 active and standby temperatures to 0C M302 S120 R110 ; Allow extrusion starting from 120°C and retractions already from 110°C M302 P1 ;allows cold extrusion with RepRap, otherwise "M302" alone works T0 ;selects tool0;M563 S1 ;allows for tool nomenclature compatibility between Slic3r and RepRap (Tools 0&1 vs Toos 1&2) I don't even want to do homing yet because my endstops are still screwed up, fortunately for my purposes I don't actually require them to work to get. 168. Only users with topic management privileges can see it. Retract 150 mm of filament, then remove it from the filament drive. the 0, 1,2 drivers still work fine. This topic has been deleted. The button movement range is about 0. M302. dmould. Direct drive: Remove your nozzle, hotend, or extruder. Then reduce the distance, and stop just before the filament disappears into the hot end. Fan1 configured in thermostatic mode by default. 0 S1 ; Enable network and acquire dynamic address via DHCP M586 P0 S1 ; Enable HTTPThermostatic control is turned on. M302 P1 allows cold extrusion (RepRapFirmware). Only users with topic management privileges can see it. I have been clicking the 'retract' and 'extrude' button multiple times to push the plunger down to the correct position and to retract the plunger from the bottom of the cylinder after the print. Extrude a little more filament: G1 E20 F200; Measure as accurately as you can using a rule between your marks. 3 ; Filter. Thermostatic control is turned on > 45C turn on ;M106 P1 S255 H-1 M302 P1 ; Allow cold extrusion (for testing) T0 ; Set tool 0 (default extruder) G21 ; Work in millimetres G90 ; Send absolute coordinates. 0. Sending M302 P1 shows green as though it accepts the command, but the extrude & retract buttons are still grayed out. Recently i have been testing the clay extruder connected to the Driver0 on Duet 3 Mainboard 6HC. 03) ; executed by the firmware on start-up ; ; generated by RepRapFirmware Configuration Tool v2. g. Reply Quote. I am setting up a Delta printer with Ramps 1. Business, Economics, and Finance. Business, Economics, and Finance. @o_lampe said in Error: Driver 5 does not support x1 microstepping: M584 X0 Y1 Z2 E5 ; set drive mapping M569 P5 S1 T25:25:25:25 ; physical drive 5 is external (DUE) M350 E1 ; no microsteps,. GameStop Moderna Pfizer Johnson & Johnson AstraZeneca Walgreens Best Buy Novavax SpaceX Tesla. 9 ;extrude 0. 5mm/sec echo "Done" M82 ; set extruder to abs modeBusiness, Economics, and Finance. M302 P1 ;allows cold extrusion with RepRap, otherwise "M302" alone works T0 ;selects tool0;M563 S1 ;allows for tool nomenclature compatibility between Slic3r and RepRap (Tools 0&1 vs Toos 1&2) I don't even want to do homing yet because my endstops are still screwed up, fortunately for my purposes I don't actually require them to work to. Sending M302 P1 shows green as though it accepts the command, but the extrude & retract buttons are still grayed out. The SMuFF is supposed to beep for 1 second. Pix4d often makes vertical surfaces to 45 deg where they meet the ground. 3 mm and released @ about 0. Just need to find settings for Slice Engineering 300c thermistor, the temp reading slightly higher than actual measured with an TC thermometer. Can you share output of M122 command and try cold extrude using M302 P1 it'll enable extrude button. G92 X0 Y0 Z0 ; set current position to {X=0,Y=0,Z=0} G92 E0 ;zero the extruded length. 5mm/sec echo "Done" M82 ; set extruder to abs mode 1 Reply Last reply Reply Quote 0M574 Y1 S1 P"!P1. send T0), and enable cold extrusion with M302 P1. @deckingman please find ;Cold extrusion M302 P1 ; allow cold extrusion ; Drives M569 P0 S1 ; physical drive 0 goes forwards M569 P1 S1 ; physical drive 1 goes forwards M569 P2 S1. @agent0810 said in Homing advice: the z is at 0 at the top, so it cant go lower right? shouldnt it home at 300 something? im having issues moveing the bed. M302 P1 ; Allow Cold extrudes M98 Pmachine_maxtemp. 1 Reply Last reply Reply Quote 0. extrusion temperature 160. . 0 D9. Set the temperature (and enable) using. M302 P1; Axis Limits M208 X-50 Y0 Z0 U0 S1 ; set axis minima M208 X210 Y220 U260 Z200 S0 ; set axis maxima ; Endstops M574 X1 S1 P"io0" ; configure switch-type (e. PROMEGA I have installed a BL Touch clone and it works with the direct commands. g. M302 P1 ; Allow cold extrusion M82 ; use absolute distances for extrusion G92 E0 ; Reset Extruder G1 E-430 F3600 ; retract 430 mm M302 P0 ; Disable cold extrusion T-1 P0 ; Deselect all tools without running any tool change macros. Re: Extrude without a Hotend May 04, 2017 11:25PM. To test for this, with the power off swap the E0 connector on the Duet with another one e. 0.